{"product_id":"20ft-cat-5e-cmr-non-boot-patch-cable-gray","title":"20Ft Cat.5E CMR Non-Boot Patch Cable Gray","description":"\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/C5CMRData.pdf?v=1763566433\" target=\"blank\" class=\"btn btn-default\"\u003eData Sheet\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/C5CMRspec.pdf?v=1763566438\" target=\"blank\" class=\"btn btn-default\"\u003eData Sheet\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/patchcableqtychart.pdf?v=1763479209\" target=\"blank\" class=\"btn btn-default\"\u003eCase Qty Chart\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/100450pack.pdf?v=1763566443\" target=\"blank\" class=\"btn btn-default\"\u003ePackaging\u003c\/a\u003e \u003cbr\u003e\n\n\u003cp\u003eNetwork cable comes with different ratings, either 'CM', 'CMR' or 'CMP', as well as 'UL'.  These cable rating codes mean that the cables meets different UL-NEC requirements based mostly on cable jacket quality concerning fire hazard.\n\n\u003cstrong\u003eCM\u003c\/strong\u003e : CM rated cables are used for general building wiring including residential installation. These cables are resistant to the spread of fire and pass the UL 1581 Vertical Tray Flame Test. When it's just called a patch cable, it is typically CM rated jacket.\n\n\u003cstrong\u003eCMR\u003c\/strong\u003e : The 'R' in CRM is for 'Riser'.  Riser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications. \n\n\u003cstrong\u003eCMP\u003c\/strong\u003e : The 'P' in CMP is for Plenum. Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for fire resistance and low-smoke and toxin producing characteristics. \n\nIn general, fire resistance requirement becomes higher in this order; CM -\u0026gt; CMR -\u0026gt; CMP. CMP produces the least smoke and toxic fume when burnt.\n\nTypical patch cables are CM rated and suitable for general building installation. Our CMR series specifically uses CMR rated jacket for installations where higher fire resistance is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/CMR.jpg?v=1763566448\" width=\"750\" height=\"198\"\u003e\u003c\/p\u003e\u003cfont color=\"#333333\"\u003e\u003cstrong\u003eBestLink Netware patch cables are made of 100% pure copper wire and 50 micron gold plated RJ45 plugs. We do not use CCA (aluminum wire). \u003cfont color=\"#0033FF\"\u003e\u003ca href=\"https:\/\/www.bestlinknetware.com\/products\/50micron.htm\" target=\"blank\" class=\"btn btn-default\"\u003e\u003cstrong\u003eWhy 50 micron gold plating?\u003c\/strong\u003e\u003c\/a\u003e\u003c\/font\u003e \u003cbr\u003e\u003c\/strong\u003e\u003c\/font\u003e\u003cfont color=\"#0033FF\"\u003e\u003ca href=\"https:\/\/www.bestlinknetware.com\/products\/cca.htm\" target=\"blank\" class=\"btn btn-default\"\u003e\u003cstrong\u003eWhat is CCA?\u003c\/strong\u003e\u003c\/a\u003e\u003c\/font\u003e\u003cp\u003e* Designed For: Network Adapt?ers, Hubs, Switches, Routers, DSL\/Cable Modems,  Patch Panels and other Computer Networking applications.\u003cbr\u003e* Certification: TIA\/EIA\u003cbr\u003e* T-568B  standard wiring\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/568B.gif?v=1763480283\" width=\"230\" height=\"150\"\u003e \u003c\/p\u003e\n* Cat.5E rated UTP (Unshielded Twist Pair) patch cable\n* CMR (Riser) Jacket\n* 24AWG 4pair stranded pure copper wire\n* 50 micron gold plated short body RJ45 plug\n* RoHS compliant\n\u003cbr\u003e\u003cbr\u003eFAQ\u003cbr\u003e\u003ctable width=\"100%\" border=\"0\" cellpadding=\"0\" cellspacing=\"1\" bgcolor=\"#666666\"\u003e  \u003ctr\u003e    \u003ctd width=\"17%\"\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd height=\"100%\"\u003e TIA\/EIA              \u003cbr\u003e              \u003cbr\u003e            \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd width=\"83%\"\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eTIA\/EIA is abbreviation of Telecommunication Industry Association and  Electronics Industry Alliance that sets telecommunication standards in the US. BestLink Netware patch cable complies with the latest TIA\/EIA telecommunication cable standards.            \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd height=\"100%\"\u003eT-568B Wiring          \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e \u003ctd\u003eThere are two standards for wiring color code, 5???68A and 568B. While there's no difference in connectivity between 568A and 568B, 568B is the most prevalent wi  ring color code in the US. Our patch cable is 568B wired.\u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd height=\"100%\"\u003eUTP and STP          \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eUTP is Unshielded Twisted Pair and STP is Shielded Twisted Pair. STP cable is wrapped in metal foil or braid. Both have the same Ethernet communication performance, but STP has better protection against Electro-Magnetis noise from outside. UTP is accepted for residential and general commercial installation.\u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd height=\"100%\"\u003eCMR rated jacket          \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eRiser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications.            \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd height=\"100%\"\u003e24AWG and Stranded          \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eAWG (American Wire Gauge) indicates wire thickness. Higher the number, thinner the wire. 24AWG or 26AWG is commonly used for ethernet cables. Stranded wire is a bundle of thin wires as oposed to solid wire that is single solid wire. Stranded wire is more flexible than solid wire and commonly used for indoor network wiring such as patch cable.\u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eRoHS          \u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e    \u003ctd\u003e\u003ctable width=\"100%\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e        \u003ctr\u003e          \u003ctd\u003eRestriction of Hazardous Substances Directive. This directive restricts the use of hazardous materials such as lead or mercury in the manufacture of electronic and electrical equipments. BestLink Netware cables are all RoHS compliant.\u003c\/td\u003e        \u003c\/tr\u003e      \u003c\/table\u003e\u003c\/td\u003e  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Bestlink Netware Inc","offers":[{"title":"Default Title","offer_id":45141386559545,"sku":"100464GY","price":2.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0745\/6427\/2185\/files\/100450GY-1_ab9fc24f-1a6a-45ca-bb4b-ccf306097de6.jpg?v=1762341309","url":"https:\/\/na2bp0-qq.myshopify.com\/products\/20ft-cat-5e-cmr-non-boot-patch-cable-gray","provider":"Bestlink Netware Inc","version":"1.0","type":"link"}